Devyami

Clean water in

Ultrafiltration (UF)

Particles and microbes out. Minerals stay in.

Ultrafiltration is a membrane filter with pores far finer than any sand bed — fine enough to stop bacteria and colloids — yet open enough to let dissolved minerals through. It needs only low pressure and wastes little water.

Feed water Hollow-fibre UF module Clean water (permeate) To drain on backwash particles & bacteria held water & minerals pass

What it means

A UF membrane is a bundle of thousands of hollow fibres, each like a thin straw whose wall is full of microscopic pores, typically around a hundredth of a micron to a tenth. Water is pushed through the fibre walls; what is bigger than the pores stays behind.

That pore size is the point. It is small enough to hold back suspended solids, colloids, bacteria and most cysts, giving clear water with a consistently low turbidity. It is large enough that dissolved salts and minerals pass, so the water keeps its character.

UF is often used just before an RO plant: it hands the RO membranes clean, particle-free water, which is what they need to last.

How it works

Step by step, as drawn in the diagram above.

  1. 1

    Feed water in

    Pre-filtered water is pumped into the UF module at low pressure.

  2. 2

    Through the fibre walls

    Water passes through the pores in the hollow-fibre walls; particles, colloids and bacteria are held on the surface.

  3. 3

    Clean permeate out

    The filtered water — the permeate — collects and leaves the module.

  4. 4

    Backwash

    At intervals, permeate is pushed back the other way to lift what has gathered on the fibres and flush it to drain.

Keeping the fibres clean

UF runs in short cycles: filter, then backwash, with occasional chemical cleaning.

  1. 1 Filtration Water passes through the fibre walls; solids build up on the surface.
  2. 2 Backwash Permeate is reversed through the fibres to lift the layer off, often every few tens of minutes.
  3. 3 Chemically enhanced backwash Periodically a dilute chemical is added to the backwash to remove what water alone cannot.
  4. 4 Clean-in-place Occasionally the module is soaked in cleaning solution to restore its flow.

What it takes out

  • Suspended solids and turbidity
  • Colloids
  • Bacteria and most cysts
  • Much of the larger organic matter

What it does not

  • Dissolved salts and minerals (TDS)
  • Hardness
  • Dissolved gases and some dissolved organics

Where it is used

  • Safe water where TDS is already acceptable
  • Pre-treatment ahead of RO
  • Apartments and campuses
  • Food and beverage pre-treatment
  • Recycled water polishing

What we size it on

  • Required flow of filtered water
  • Turbidity and solids in the feed
  • Feed water temperature
  • Backwash frequency and the water it uses

Looking after it

  • Keep pre-filtration working — UF should not see heavy silt
  • Watch trans-membrane pressure; a steady rise means cleaning is due
  • Carry out chemical cleaning as scheduled
  • Integrity-test modules periodically

Questions, answered

What is the difference between UF and RO? +

UF stops particles, colloids and bacteria but lets dissolved minerals through, at low pressure and with little waste. RO also removes dissolved salts, needs a high-pressure pump and produces a reject stream.

Does UF reduce TDS? +

No. Dissolved salts pass through UF membranes. If TDS is high, an RO is needed.

Why put UF before an RO? +

RO membranes foul quickly when particles reach them. UF delivers consistently clean feed, so the RO runs longer between cleans.

Send us your water report

Or tell us where your water comes from — we design the treatment train, install it and stand behind it.