Devyami
Motor Driver

Motor Driver

Starter, controller and motor protection for one pump — single or three phase.

The APCON Motor Driver takes your old starter panel's place. It runs one pump on tank level, pressure, temperature, flow or a timer, protects the motor against nine faults, and reports everything to the Devyami app.

Supply Single phase (1Φ) or three phase (3Φ) versions
Pumps One
Applications Level · pressure · temperature (hot or cold) · dewatering · manual
Modes Auto · semi-auto · manual
Control logic Time delay · proportional · PID
Tank inputs Source and destination tank — float, conductive probe or level transmitter
Pressure input Pressure transducer, 0.5–4.5 V or 4–20 mA
Other inputs Flow meter (pulse or Modbus) · TDS or temperature sensor · external start / stop / trip contact
Energy metering Voltage, current, power factor, frequency and THD on every phase
Protections Dry run (power-based and sensor-based) · overload · under load · under and over voltage · phase loss, weak phase and phase sequence (3Φ) · over-cycle · over-run
Timers 8 on-times and 8 off-times · real-time clock · delays remembered through a power cut
Panel 128 × 64 OLED display · 5-button keypad · status LEDs
Connectivity Wi-Fi to the Devyami app and web portal · over-the-air updates · RS485 Modbus RTU for SCADA, PLC and BMS

One box instead of a starter panel

The Motor Driver is not an add-on next to your starter — it is the starter, with the controller and the protection built in. It goes on the wall where the old panel was, onto the pump, tanks and wiring you already have. A single-pump retrofit is usually a few hours.

What it decides on

Tell it what the pump is for and it runs itself:

  • Level — start when the destination tank is low and the source has water, stop when it is full. See tank level automation.
  • Pressure — hold a set pressure with PID control on a pressure transducer. See pressure boosting.
  • Temperature — run a circulation or cooling pump on a temperature band.
  • Dewatering — the level rule inverted, so a pit or basement sump is emptied instead of filled.
  • Timers — up to eight on-times and eight off-times, kept by its own real-time clock.

Protection that does not need the internet

Every protection runs on the controller itself, so a motor is protected with the router unplugged. Dry run is caught two ways: by a sensor at the source, and without any sensor by watching true input power, which collapses the moment a pump loses water. All nine are explained on the motor protection page.

What it is used for

Each page shows the system working — the diagram, the logic and how it is installed.

Get this product

Devyami products are sold and installed through our dealer network, so your system arrives commissioned, connected and supported locally. Request a quote and we'll route it to the dealer nearest you — with this product's details already attached.

Request a quote for Motor Driver

We'll only use these details to respond to your enquiry. See our privacy policy.